Endress + Hauser CLS21-L1N2A Conductivity 2-electrode sensor Application: medium/high conductivity Water treatment, phase separation Process temperature max 135C Process pressure max 16 bar (20oC) ATEX II 1G EEx ia IIC T3/T4/T6 / FM Materials: graphite, titanium, PES Quality … [Read more...] about CLS21-L1N2A
Endress + Hauser Condumax CLS21 Analog conductivity sensor for all process and environmental applications
Endress + Hauser Condumax CLS21 Condumax CLS21 is a robust conductivity sensor for all process and environmental applications.
2-electrode system with parallel arranged electrodes.
Conductivity sensor Condumax CLS21 measured values:
- Conductivity
- Temperature
Endress + Hauser Conductivity sensor Condumax CLS21 measuring ranges:
Conductivity
k=1: 10,0 µS/cm - 20,0 mS/cm
Temperature
-20 to 135 °C / -4 to 275 °F
Endress + Hauser Conductivity sensor Condumax CLS21 application:
Condumax CLS21 measures conductivity in all process and environmental applications, such as:
• Potable water treatment
• Desalination plants
• Industrial water treatment
• River/lake monitoring
• Phase separation in medium conductivities (e.g. milk/water)
With its international explosion protection approvals, such as ATEX and FM, the sensor is suitable for hazardous area use.
Endress + Hauser Conductivity sensor Condumax CLS21 advantages are:
• Reliable and accurate measuring values at medium to high conductivities
• Robust design for long durability and low maintenance
• High chemical, thermal and mechanical stability
• Quality certificate stating the individual cell constant
Endress + Hauser Available Conductivity sensor Condumax CLS21 process temperature:
max. 135°C / max. 275°F
Endress + Hauser Available Conductivity sensor Condumax CLS21 process pressure:
max. 16 bar at 20°С / max. 232psi at 68°F
CLS21-C2B4A
Endress + Hauser CLS21-C2B4A Conductivity 2-electrode sensor Application: medium/high conductivity Water treatment, phase separation Process temperature max 135C Process pressure max 16 bar (20oC) ATEX II 1G EEx ia IIC T3/T4/T6 / FM Materials: graphite, titanium, PES Quality … [Read more...] about CLS21-C2B4A
CLS21-C3B2A
Endress + Hauser CLS21-C3B2A Conductivity 2-electrode sensor Application: medium/high conductivity Water treatment, phase separation Process temperature max 135C Process pressure max 16 bar (20oC) ATEX II 1G EEx ia IIC T3/T4/T6 / FM Materials: graphite, titanium, PES Quality … [Read more...] about CLS21-C3B2A
CLS21-C2A4A
Endress + Hauser CLS21-C2A4A Conductivity 2-electrode sensor Application: medium/high conductivity Water treatment, phase separation Process temperature max 135C Process pressure max 16 bar (20oC) ATEX II 1G EEx ia IIC T3/T4/T6 / FM Materials: graphite, titanium, PES Quality … [Read more...] about CLS21-C2A4A
CLS21-L2B4A
Endress + Hauser CLS21-L2B4A Conductivity 2-electrode sensor Application: medium/high conductivity Water treatment, phase separation Process temperature max 135C Process pressure max 16 bar (20oC) ATEX II 1G EEx ia IIC T3/T4/T6 / FM Materials: graphite, titanium, PES Quality … [Read more...] about CLS21-L2B4A
CLS21-C2A4A
Endress + Hauser CLS21-C2A4A Conductivity 2-electrode sensor Application: medium/high conductivity Water treatment, phase separation Process temperature max 135C Process pressure max 16 bar (20oC) ATEX II 1G EEx ia IIC T3/T4/T6 / FM Materials: graphite, titanium, PES Quality … [Read more...] about CLS21-C2A4A
CLS21-L3B3A
Endress + Hauser CLS21-L3B3A Conductivity 2-electrode sensor Application: medium/high conductivity Water treatment, phase separation Process temperature max 135C Process pressure max 16 bar (20oC) ATEX II 1G EEx ia IIC T3/T4/T6 / FM Materials: graphite, titanium, PES Quality … [Read more...] about CLS21-L3B3A
CLS21-L1E4A
Endress + Hauser CLS21-L1E4A Conductivity 2-electrode sensor Application: medium/high conductivity Water treatment, phase separation Process temperature max 135C Process pressure max 16 bar (20oC) ATEX II 1G EEx ia IIC T3/T4/T6 / FM Materials: graphite, titanium, PES Quality … [Read more...] about CLS21-L1E4A
CLS21-L2A4A
Endress + Hauser CLS21-L2A4A Conductivity 2-electrode sensor Application: medium/high conductivity Water treatment, phase separation Process temperature max 135C Process pressure max 16 bar (20oC) ATEX II 1G EEx ia IIC T3/T4/T6 / FM Materials: graphite, titanium, PES Quality … [Read more...] about CLS21-L2A4A
CLS21-C1N3A
Endress + Hauser CLS21-C1N3A Conductivity 2-electrode sensor Application: medium/high conductivity Water treatment, phase separation Process temperature max 135C Process pressure max 16 bar (20oC) ATEX II 1G EEx ia IIC T3/T4/T6 / FM Materials: graphite, titanium, PES Quality … [Read more...] about CLS21-C1N3A
CLS21-L1N3A
Endress + Hauser CLS21-L1N3A Conductivity 2-electrode sensor Application: medium/high conductivity Water treatment, phase separation Process temperature max 135C Process pressure max 16 bar (20oC) ATEX II 1G EEx ia IIC T3/T4/T6 / FM Materials: graphite, titanium, PES Quality … [Read more...] about CLS21-L1N3A
CLS21-L3B4A
Endress + Hauser CLS21-L3B4A Conductivity 2-electrode sensor Application: medium/high conductivity Water treatment, phase separation Process temperature max 135C Process pressure max 16 bar (20oC) ATEX II 1G EEx ia IIC T3/T4/T6 / FM Materials: graphite, titanium, PES Quality … [Read more...] about CLS21-L3B4A
CLS21-C1E4A
Endress + Hauser CLS21-C1E4A Conductivity 2-electrode sensor Application: medium/high conductivity Water treatment, phase separation Process temperature max 135C Process pressure max 16 bar (20oC) ATEX II 1G EEx ia IIC T3/T4/T6 / FM Materials: graphite, titanium, PES Quality … [Read more...] about CLS21-C1E4A
CLS21-C2B4A
Endress + Hauser CLS21-C2B4A Conductivity 2-electrode sensor Application: medium/high conductivity Water treatment, phase separation Process temperature max 135C Process pressure max 16 bar (20oC) ATEX II 1G EEx ia IIC T3/T4/T6 / FM Materials: graphite, titanium, PES Quality … [Read more...] about CLS21-C2B4A
CLS21-L3B2A
Endress + Hauser CLS21-L3B2A Conductivity 2-electrode sensor Application: medium/high conductivity Water treatment, phase separation Process temperature max 135C Process pressure max 16 bar (20oC) ATEX II 1G EEx ia IIC T3/T4/T6 / FM Materials: graphite, titanium, PES Quality … [Read more...] about CLS21-L3B2A
CLS21-C1N2A
Endress + Hauser CLS21-C1N2A Conductivity 2-electrode sensor Application: medium/high conductivity Water treatment, phase separation Process temperature max 135C Process pressure max 16 bar (20oC) ATEX II 1G EEx ia IIC T3/T4/T6 / FM Materials: graphite, titanium, PES Quality … [Read more...] about CLS21-C1N2A
CLS21-C3B4A
Endress + Hauser CLS21-C3B4A Conductivity 2-electrode sensor Application: medium/high conductivity Water treatment, phase separation Process temperature max 135C Process pressure max 16 bar (20oC) ATEX II 1G EEx ia IIC T3/T4/T6 / FM Materials: graphite, titanium, PES Quality … [Read more...] about CLS21-C3B4A
CLS21-L2A4A
Endress + Hauser CLS21-L2A4A Conductivity 2-electrode sensor Application: medium/high conductivity Water treatment, phase separation Process temperature max 135C Process pressure max 16 bar (20oC) ATEX II 1G EEx ia IIC T3/T4/T6 / FM Materials: graphite, titanium, PES Quality … [Read more...] about CLS21-L2A4A
CLS21-C3B3A
Endress + Hauser CLS21-C3B3A Conductivity 2-electrode sensor Application: medium/high conductivity Water treatment, phase separation Process temperature max 135C Process pressure max 16 bar (20oC) ATEX II 1G EEx ia IIC T3/T4/T6 / FM Materials: graphite, titanium, PES Quality … [Read more...] about CLS21-C3B3A