Endress + Hauser CLS15-B1A1A Conductivity 2-electrode sensor Condumax Application: pure water, ultrapure water ATEX II 1G EEx ia IIC T3/T4/T6 / FM Materials: 316L, PES Quality certificate calibration Endress Hauser CLS15 B Measuring Range; Cell Constant: 0.1-200uS/cm; k=0.1 … [Read more...] about CLS15-B1A1A
Endress + Hauser CLS15 conductivity sensor Condumax CLS 15 analog
Endress + Hauser conductivity sensor Condumax CLS15, analog, conductivity sensor for standard applications in pure and ultrapure water
Conductivity sensor Condumax CLS15 measured values:
- Conductivity
- Temperature
Conductivity sensor Condumax CLS15 measuring range:
Conductivity (in relation to water at 25 °C (77 °F)
k=0,01: 0-20 µS/cm
k=0,1: 0-200 µS/cm
Temperature
-20 to 140 °C (-4 to 280 °F)
Conductivity sensor Condumax CLS15 application:
Condumax CLS15 measures conductivity in pure and ultrapure water applications for the monitoring and control of:
• Ion exchangers
• Reverse osmosis
• Cooling water
• Distillation
• Chip cleaning
The sensor can be used in power plants for:
• Degassed conductivity
• pH measurement with differential conductivity
With its international explosion protection approvals, such as ATEX and FM, the sensor is suitable for hazardous area use.
Conductivity sensor Condumax CLS15 advantages are:
• Reliable and accurate measuring values at low conductivities
• Easy to clean thanks to polished measuring surfaces
• Sterilizable
• Robust design for high durability
• Different cell constants provide a wide measuring range
• Quality certificate stating the individual cell constant
Available Conductivity sensor Condumax CLS15 process temperature:
Threaded version with fixed cable -20 to 100 °C (-4 to 212 °F)
Threaded version with plug-in head, Clamp version
Normal operation -20 to 120 °C (-4 to 248 °F)
Sterilization (max. 1 h) max. 140 °C (284 °F)
1) threaded versions: max. 30 minutes
Available Conductivity sensor Condumax CLS15 process pressure range (absolute):
13 bar (188 psi) at 20 °C (68 °F)
1 bar (14 psi) at 120 °C (248 °F)
CLS15-L1M1A
Endress + Hauser CLS15-L1M1A Conductivity 2-electrode sensor Condumax Application: pure water, ultrapure water ATEX II 1G EEx ia IIC T3/T4/T6 / FM Materials: 316L, PES Quality certificate calibration Endress Hauser CLS15 L Measuring Range; Cell Constant: PWIS free for k=0,1 … [Read more...] about CLS15-L1M1A
CLS15-L1A1A
Endress + Hauser CLS15-L1A1A Conductivity 2-electrode sensor Condumax Application: pure water, ultrapure water ATEX II 1G EEx ia IIC T3/T4/T6 / FM Materials: 316L, PES Quality certificate calibration Endress Hauser CLS15 L Measuring Range; Cell Constant: PWIS free for k=0,1 … [Read more...] about CLS15-L1A1A
CLS15-A1A1A
Endress + Hauser CLS15-A1A1A Conductivity 2-electrode sensor Condumax Application: pure water, ultrapure water ATEX II 1G EEx ia IIC T3/T4/T6 / FM Materials: 316L, PES Quality certificate calibration Endress Hauser CLS15 A Measuring Range; Cell Constant: 0.04-20uS/cm; k=0.01 … [Read more...] about CLS15-A1A1A
CLS15-B1M3A
Endress + Hauser CLS15-B1M3A Conductivity 2-electrode sensor Condumax Application: pure water, ultrapure water ATEX II 1G EEx ia IIC T3/T4/T6 / FM Materials: 316L, PES Quality certificate calibration Endress Hauser CLS 15 B Measuring Range; Cell Constant: 0.1-200uS/cm; k=0.1 … [Read more...] about CLS15-B1M3A
CLS15-A3D1A
Endress + Hauser CLS15-A3D1A Conductivity 2-electrode sensor Condumax Application: pure water, ultrapure water ATEX II 1G EEx ia IIC T3/T4/T6 / FM Materials: 316L, PES Quality certificate calibration Endress Hauser CLS15 A Measuring Range; Cell Constant: 0.04-20uS/cm; k=0.01 … [Read more...] about CLS15-A3D1A
CLS15-L1M3A
Endress + Hauser CLS15-L1M3A Conductivity 2-electrode sensor Condumax Application: pure water, ultrapure water ATEX II 1G EEx ia IIC T3/T4/T6 / FM Materials: 316L, PES Quality certificate calibration Endress Hauser CLS 15 L Measuring Range; Cell Constant: PWIS free for k=0,1 … [Read more...] about CLS15-L1M3A
CLS15-B4D1A
Endress + Hauser CLS15-B4D1A Conductivity 2-electrode sensor Condumax Application: pure water, ultrapure water ATEX II 1G EEx ia IIC T3/T4/T6 / FM Materials: 316L, PES Quality certificate calibration Endress Hauser CLS15 B Measuring Range; Cell Constant: 0.1-200uS/cm; k=0.1 … [Read more...] about CLS15-B4D1A
CLS15-A3D3A
Endress + Hauser CLS15-A3D3A Conductivity 2-electrode sensor Condumax Application: pure water, ultrapure water ATEX II 1G EEx ia IIC T3/T4/T6 / FM Materials: 316L, PES Quality certificate calibration Endress Hauser CLS 15 A Measuring Range; Cell Constant: 0.04-20uS/cm; k=0.01 … [Read more...] about CLS15-A3D3A
CLS15-A4D1A
Endress + Hauser CLS15-A4D1A Conductivity 2-electrode sensor Condumax Application: pure water, ultrapure water ATEX II 1G EEx ia IIC T3/T4/T6 / FM Materials: 316L, PES Quality certificate calibration Endress Hauser CLS15 A Measuring Range; Cell Constant: 0.04-20uS/cm; k=0.01 … [Read more...] about CLS15-A4D1A
CLS15-A1M1A
Endress + Hauser CLS15-A1M1A Conductivity 2-electrode sensor Condumax Application: pure water, ultrapure water ATEX II 1G EEx ia IIC T3/T4/T6 / FM Materials: 316L, PES Quality certificate calibration Endress Hauser CLS15 A Measuring Range; Cell Constant: 0.04-20uS/cm; k=0.01 … [Read more...] about CLS15-A1M1A
CLS15-B3D3A
Endress + Hauser CLS15-B3D3A Conductivity 2-electrode sensor Condumax Application: pure water, ultrapure water ATEX II 1G EEx ia IIC T3/T4/T6 / FM Materials: 316L, PES Quality certificate calibration Endress Hauser CLS 15 B Measuring Range; Cell Constant: 0.1-200uS/cm; k=0.1 … [Read more...] about CLS15-B3D3A
CLS15-A1M3A
Endress + Hauser CLS15-A1M3A Conductivity 2-electrode sensor Condumax Application: pure water, ultrapure water ATEX II 1G EEx ia IIC T3/T4/T6 / FM Materials: 316L, PES Quality certificate calibration Endress Hauser CLS 15 A Measuring Range; Cell Constant: 0.04-20uS/cm; k=0.01 … [Read more...] about CLS15-A1M3A
CLS15-A4D3A
Endress + Hauser CLS15-A4D3A Conductivity 2-electrode sensor Condumax Application: pure water, ultrapure water ATEX II 1G EEx ia IIC T3/T4/T6 / FM Materials: 316L, PES Quality certificate calibration Endress Hauser CLS 15 A Measuring Range; Cell Constant: 0.04-20uS/cm; k=0.01 … [Read more...] about CLS15-A4D3A
CLS15-L3D3A
Endress + Hauser CLS15-L3D3A Conductivity 2-electrode sensor Condumax Application: pure water, ultrapure water ATEX II 1G EEx ia IIC T3/T4/T6 / FM Materials: 316L, PES Quality certificate calibration Endress Hauser CLS 15 L Measuring Range; Cell Constant: PWIS free for k=0,1 … [Read more...] about CLS15-L3D3A
CLS15-B1M1A
Endress + Hauser CLS15-B1M1A Conductivity 2-electrode sensor Condumax Application: pure water, ultrapure water ATEX II 1G EEx ia IIC T3/T4/T6 / FM Materials: 316L, PES Quality certificate calibration Endress Hauser CLS15 B Measuring Range; Cell Constant: 0.1-200uS/cm; k=0.1 … [Read more...] about CLS15-B1M1A
CLS15-L3D1A
Endress + Hauser CLS15-L3D1A Conductivity 2-electrode sensor Condumax Application: pure water, ultrapure water ATEX II 1G EEx ia IIC T3/T4/T6 / FM Materials: 316L, PES Quality certificate calibration Endress Hauser CLS15 L Measuring Range; Cell Constant: PWIS free for k=0,1 … [Read more...] about CLS15-L3D1A
CLS15-B3D2A
Endress + Hauser CLS15-B3D2A Conductivity 2-electrode sensor Condumax Application: pure water, ultrapure water ATEX II 1G EEx ia IIC T3/T4/T6 / FM Materials: 316L, PES Quality certificate calibration Endress Hauser CLS 15 B Measuring Range; Cell Constant: 0.1-200uS/cm; k=0.1 … [Read more...] about CLS15-B3D2A
CLS15-L3D2A
Endress + Hauser CLS15-L3D2A Conductivity 2-electrode sensor Condumax Application: pure water, ultrapure water ATEX II 1G EEx ia IIC T3/T4/T6 / FM Materials: 316L, PES Quality certificate calibration Endress Hauser CLS 15 L Measuring Range; Cell Constant: PWIS free for k=0,1 … [Read more...] about CLS15-L3D2A
CLS15-B4D3A
Endress + Hauser CLS15-B4D3A Conductivity 2-electrode sensor Condumax Application: pure water, ultrapure water ATEX II 1G EEx ia IIC T3/T4/T6 / FM Materials: 316L, PES Quality certificate calibration Endress Hauser CLS 15 B Measuring Range; Cell Constant: 0.1-200uS/cm; k=0.1 … [Read more...] about CLS15-B4D3A
CLS15-L4D2A
Endress + Hauser CLS15-L4D2A Conductivity 2-electrode sensor Condumax Application: pure water, ultrapure water ATEX II 1G EEx ia IIC T3/T4/T6 / FM Materials: 316L, PES Quality certificate calibration Endress Hauser CLS 15 L Measuring Range; Cell Constant: PWIS free for k=0,1 … [Read more...] about CLS15-L4D2A
CLS15-A1A2A
Endress + Hauser CLS15-A1A2A Conductivity 2-electrode sensor Condumax Application: pure water, ultrapure water ATEX II 1G EEx ia IIC T3/T4/T6 / FM Materials: 316L, PES Quality certificate calibration Endress Hauser CLS15 A Measuring Range; Cell Constant: 0.04-20uS/cm; k=0.01 … [Read more...] about CLS15-A1A2A
CLS15-L1A3A
Endress + Hauser CLS15-L1A3A Conductivity 2-electrode sensor Condumax Application: pure water, ultrapure water ATEX II 1G EEx ia IIC T3/T4/T6 / FM Materials: 316L, PES Quality certificate calibration Endress Hauser CLS 15 L Measuring Range; Cell Constant: PWIS free for k=0,1 … [Read more...] about CLS15-L1A3A
CLS15-B1A3A
Endress + Hauser CLS15-B1A3A Conductivity 2-electrode sensor Condumax Application: pure water, ultrapure water ATEX II 1G EEx ia IIC T3/T4/T6 / FM Materials: 316L, PES Quality certificate calibration Endress Hauser CLS 15 B Measuring Range; Cell Constant: 0.1-200uS/cm; k=0.1 … [Read more...] about CLS15-B1A3A
CLS15-A3D2A
Endress + Hauser CLS15-A3D2A Conductivity 2-electrode sensor Condumax Application: pure water, ultrapure water ATEX II 1G EEx ia IIC T3/T4/T6 / FM Materials: 316L, PES Quality certificate calibration Endress Hauser CLS 15 A Measuring Range; Cell Constant: 0.04-20uS/cm; k=0.01 … [Read more...] about CLS15-A3D2A
CLS15-L1A2A
Endress + Hauser CLS15-L1A2A Conductivity 2-electrode sensor Condumax Application: pure water, ultrapure water ATEX II 1G EEx ia IIC T3/T4/T6 / FM Materials: 316L, PES Quality certificate calibration Endress Hauser CLS15 L Measuring Range; Cell Constant: PWIS free for k=0,1 … [Read more...] about CLS15-L1A2A
CLS15-L1M2A
Endress + Hauser CLS15-L1M2A Conductivity 2-electrode sensor Condumax Application: pure water, ultrapure water ATEX II 1G EEx ia IIC T3/T4/T6 / FM Materials: 316L, PES Quality certificate calibration Endress Hauser CLS15 L Measuring Range; Cell Constant: PWIS free for k=0,1 … [Read more...] about CLS15-L1M2A
CLS15-B1M2A
Endress + Hauser CLS15-B1M2A Conductivity 2-electrode sensor Condumax Application: pure water, ultrapure water ATEX II 1G EEx ia IIC T3/T4/T6 / FM Materials: 316L, PES Quality certificate calibration Endress Hauser CLS15 B Measuring Range; Cell Constant: 0.1-200uS/cm; k=0.1 … [Read more...] about CLS15-B1M2A
CLS15-L4D3A
Endress + Hauser CLS15-L4D3A Conductivity 2-electrode sensor Condumax Application: pure water, ultrapure water ATEX II 1G EEx ia IIC T3/T4/T6 / FM Materials: 316L, PES Quality certificate calibration Endress Hauser CLS 15 L Measuring Range; Cell Constant: PWIS free for k=0,1 … [Read more...] about CLS15-L4D3A
CLS15-A1M2A
Endress + Hauser CLS15-A1M2A Conductivity 2-electrode sensor Condumax Application: pure water, ultrapure water ATEX II 1G EEx ia IIC T3/T4/T6 / FM Materials: 316L, PES Quality certificate calibration Endress Hauser CLS15 A Measuring Range; Cell Constant: 0.04-20uS/cm; k=0.01 … [Read more...] about CLS15-A1M2A